Stairs can be designed to comply with different regulations depending on their intended environment. Regulatory agencies are the ones who make the distinctions between stairs for commercial and industrial environments. Similar to OSHA, The International Building Code (IBC) is part of the Family of International Codes and is a public health and safety tool that outlines guidelines and safeguards from hazards associated with buildings accessible to the public. Learn the Differences Between IBC and OSHA Stairs?  OSHA Stair Requirements

IBC Requirements for Metal Stairs and Work Platforms

Commercial Stairs IBC Compliant Callouts

International Building Code Guidelines overview for commercial buildings and common stairs in buildings. It is much more complex, but these are the general codes related to stairs.

Stairways have to be at least 44″ if occupant load is over 50 and 36″ width if accessible to under 50 occupants. Stairs must have at least 80″ of head height measured off the tread nosings and it needs to be maintained for one additional riser depth at the bottom of the stairs. The riser height must be between 4″ and 7″ and the treads must be at least 11″ deep.

Stairs with winders need to be at least 11″ deep and when 12″ in from the narrow edge and the minimum depth must be 10″. ErectaStep commercial stairs with winders will be custom orders.

Stair landings a required for 12′ vertical stairs inclines and must be at least as deep as the stairs are wide (up to 4′-0″). Where a door opens into the landing it can’t project more than 7″ into the required depth of the landing.

Handrails in IBC buildings need to return to a wall, a guard or the walking surface or continue to another handrail. The IBC requires that your handrail extend 12″ past the top riser and one tread depth past the bottom riser. It is important to note that the ADA will require you to go one tread depth plus 12″ past the bottom riser so it generally overrides the IBC.

Stair handrails need to be on both sides of the stair and can’t project more than 4.5″ into the stair width on each side. On a very wide stair, you need to space intermediate handrails no more than 60″ apart. They are required to be mounted between 34″ and 38″ above the tread nosings and landings and mounted a minimum of 1.5″ off the wall. ErectaStep uses Round metal handrails and it’s required they need to 1.25″ to 2″ in diameter. While not applicable to ErectaStep’s commercial handrails, square handrails are required to have a perimeter between 4″ – 6.25″ with a maximum cross-section of 2.25″.